 Clinical Trials

Print

Home › Technology › Clinical Trials

We currently have multiple product candidates that are in various stages of research and clinical development. The following list summarizes our most advanced product candidates and their stage of development:

  • 5-FU-eluting Central Venous Catheter (“CVC”)
  • Vascular Wrap™ paclitaxel-eluting mesh
  • Bio-Seal™ biopsy track plug
  • MultiStem® stem cell therapy

5-FU-Eluting anti-infective Central Venous Catheter (“CVC”)

Central venous catheters (“CVC”) are usually inserted into critically ill patients for extended periods of time to administer fluids, drugs, and nutrition, as well as facilitate frequent blood draws. Through our proprietary drug identification strategy, we have elected to evaluate 5-Fluorouracil (“5-FU”), a drug previously approved by the FDA for treatment of various types of cancer, as a compound that may help to prevent certain types of infection in patients receiving a CVC. We recently completed a human clinical trial in the U.S. designed to assess the safety and efficacy of our 5-FU-eluting CVC in preventing various types of catheter related infections. The study was a randomized, single-blind, 960-patient, 25-center study and was designed to evaluate whether our 5-FU-eluting CVC prevents bacterial colonization at least as well as the market leading anti-infective CVC.

On July 10, 2007, we announced that we had completed enrolment of the study, and on October 9, 2007 we announced this study had met its primary statistical endpoint of non-inferiority as compared to the market leading anti-infective CVC (a chlorhexidine / silver sulfadiazine (CH-SS) coated CVC) and indicated an excellent safety profile. Based on the positive results achieved in the study, in December 2007 we filed a request for 510(k) clearance from the FDA to market and sell the CVC in the U.S.

In March 2008, we presented the clinical trial data at the 28th International Symposium on Intensive Care and Emergency Medicine (ISICEM) in Brussels, Belgium. Based on the clinical trial data, the investigators concluded that our 5-FU CVC met the primary endpoint of the study, specifically that our 5-FU CVC product candidate was non-inferior in its ability to prevent bacterial colonization of the catheter tip when compared to catheters coated with CH-SS. There were no statistically significant differences in the rate of adverse events related to the study devices, or in the rates of catheter-related bloodstream infections. Additionally, there was no evidence for acquired resistance to 5-FU in clinical isolates exposed to the drug for a second time.

On April 17, 2008, we announced that we had received 510(k) clearance from the FDA to market our 5-FU CVC in the United States.

Vascular Wrap™ paclitaxel-eluting mesh

Our paclitaxel-eluting mesh surgical implant, or Vascular Wrap, is designed to treat complications, including graft stenosis or restenosis, that may occur in connection with vascular graft implants in hemodialysis patients or in patients that have peripheral artery disease. Vascular grafts are implanted in patients in order to bypass diseased blood vessels, or to provide access to the vascular system of kidney failure patients in order to facilitate the process of hemodialysis. In many cases, these vascular grafts fail due to proliferation of cells or scar into the graft (graft stenosis or restenosis), which can negatively impact blood flow through the vascular graft.

In November 2006, we announced the results from our initial human clinical trial, which was conducted in the EU and was designed to evaluate the safety of the Vascular Wrap product in patients with peripheral artery disease in the limb. In this study, the Vascular Wrap product was well tolerated, with no adverse events being considered related to the use of the product. With the results of this trial, in November 2006 we filed for a CE Mark in order to obtain the ability to market and sell the Vascular Wrap in the EU for peripheral vascular disease.

In March 2007, we initiated a U.S. pivotal human clinical trial designed to evaluate the safety and efficacy of the Vascular Wrap in the prevention of stenosis following surgical implantation of an ePTFE vascular graft in the upper extremity for vascular (“AV”) access in hemodialysis patients. The trial enrolled its first patient in March 2007, and is designed to enroll a total of approximately 628 patients at 75 centers in the United States.

In May 2007, we initiated a European pivotal human clinical trial designed to evaluate the safety and efficacy of the Vascular Wrap in the prevention of stenosis following surgical implantation of an ePTFE vascular graft in the upper extremity for AV access in hemodialysis patients. The trial enrolled its first patient in May 2007, and is designed to enroll a total of approximately 198 patients at 20 centers in Europe.

In April 2008 we elected to suspend enrollment in its U.S. and EU human clinical trials for our Vascular Wrap product candidate in patients undergoing surgery for hemodialysis access, pending a safety review to evaluate an imbalance of infections that have been observed between the two study groups. As a result of these observations, Angiotech has elected to notify physicians to suspend further enrolment in the trials, pending a full review of the potential cause of the implant site infections. Angiotech is conducting a detailed analysis that seeks to determine the root cause of the imbalance between the two study groups, and will work with its Clinical Events Committee, the DSMB, the MHRA and the FDA to make near term decisions about any potential resumption of these clinical trials.

Bio-Seal™ biopsy track plug

Our proprietary Bio-Seal™ biopsy track plug is under evaluation in a pivotal human clinical trial. Bio-Seal™ is a novel technology designed to prevent air leaks in patients having lung biopsies by plugging the biopsy track with an expanding hydrogel plug. On contact with moist tissue, the hydrogel plug absorbs fluids and expands to fill the void created by the biopsy needle puncture. The seal is airtight and the plug is absorbed into the body after healing of the puncture site has occurred.

Bio-Seal is currently undergoing a human clinical trial in the U.S. designed to assess the safety and efficacy of Bio-Seal, with the primary endpoint being reduction in rates of pneumothorax in patients undergoing lung biopsy procedures. The clinical trial, which is expected to enroll a total of 300 patients in the U.S., is a prospective randomized multi-centered 31 safety and efficacy evaluation. The trial enrolled its first patient in October 2005. The study is designed to provide a basis for U.S. approval for the commercialization of Bio-Seal. The product has already received CE Mark approval.

MultiStem® stem cell therapy

The MultiStem stem cell therapy is under evaluation in clinical trials being conducted together with our partner Athersys, Inc. (“Athersys”) for the treatment of acute myocardial infarction. MultiStem stem cells are proprietary adult stem cells derived from bone marrow, which have demonstrated the ability in laboratory experiments to form a wide range of cell types. MultiStem may work through several mechanisms, but a primary mechanism appears to be the production of multiple therapeutic molecules produced in response to inflammation and tissue damage. We and Athersys believe that MultiStem may represent a unique “off the shelf” stem cell product candidate, based on its potential ability to be used without tissue matching or immunosupression, and its potential capacity for large scale production. We entered an agreement with Athersys in May 2006 to co-develop and commercialize MultiStem for use in the indications of acute myocardial infarction and peripheral vascular disease.

On December 20, 2007, we and Athersys announced we had received authorization from the FDA to commence a phase I human clinical trial to evaluate the safety of MultiStem in the treatment of acute myocardial infarction. Upon completion of a phase I human clinical trial currently being conducted by Athersys, we will assume lead responsibility for further clinical development. We currently own marketing and commercialization rights with respect to this product candidate.

Technology

  • Medical Devices
  • Technology Pipeline
    • Drug-Eluting Coronary Stents
    • Surgical Hemostats